dc.description.abstractIntroduction Accurate measurement of blood pressure (BP) is difficult in obese patients due to their upper arm shape and width. Errors made during BP measurement cause misdiagnosis or lead to wrong treatment. Method The data of this methodological study were collected from 40 patients who were 18 years old or above, with a BMI above 25 kg/m(2), and who were followed up with radial catheter arterial pressure in adult intensive care and postoperative care units between March and December 2020. Results In total 55% of the participants were male with a mean age of 63.9 years, mean height of 165.7 cm, mean weight of 85.2 kg and mean BMI of 31.0 +/- 2.1 kg/m(2). Intra-arterial BP (IABP) measurement values were found to be correlated with conical wrapping technique and cylindrical wrapping technique (P < 0.001). As a result, a statistically significance was found between conical SBP and intra-arterial SBP (r = 0.921; P < 0.05) and conical DBP and intra-arterial DBP (r = 0.902; P < 0.05) Conclusion It was determined that the SBP and DBP results of the conical wrapping technique were closer to the results obtained by IABP measurements. For this reason, it is more appropriate to measure BP with conical wrapping technique in clinically obese patients.en_US
dc.identifier.doi10.1097/MBP.0000000000000565
dc.identifier.endpage69en_US
dc.identifier.issn1359-5237
dc.identifier.issn1473-5725
dc.identifier.issue1en_US
dc.identifier.pmid34417375en_US
dc.identifier.scopus2-s2.0-85123274363en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage63en_US
dc.identifier.urihttps://doi.org/10.1097/MBP.0000000000000565
dc.identifier.urihttps://hdl.handle.net/20.500.14034/730
dc.identifier.volume27en_US
dc.identifier.wosWOS:000739843400011en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.journalBlood Pressure Monitoringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectblood pressureen_US
dc.subjectclinical skillsen_US
dc.subjectevidence-based practiceen_US
dc.subjectnoninvasive monitoringen_US
dc.subjectobesityen_US
dc.subjectCuffen_US
dc.subjectIndividualsen_US
dc.subjectValidationen_US
dc.subjectAccuracyen_US
dc.subjectForearmen_US
dc.titleInnovation in measuring obese patients' blood pressure: measurement with conical wrapping techniqueen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
seda şahan.pdf
Boyut:
684.53 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin / Full text