Association between Anesthesia Management and Preoperative Magnetic Resonance Image Quality in Patients Scheduled for Deep Brain Stimulation Surgery

dc.contributor.authorBilgin, Sezgin
dc.contributor.authorAslan, Kerim
dc.contributor.authorTurunç, Esra
dc.contributor.authorDost, Burhan
dc.contributor.authorAygün, Hakan
dc.contributor.authorKöksal, Ersin
dc.date.accessioned2025-03-21T07:38:01Z
dc.date.available2025-03-21T07:38:01Z
dc.date.issued2023
dc.departmentİzmir Bakırçay Üniversitesi
dc.description.abstractAim: To investigate magnetic resonance image quality and the number of motion artifact-related repeated sequences based on anesthesia or sedation management during preoperative MR imaging for DBS surgery. Material and Methods: The medical records of patients who underwent DBS procedures at the hospital of Ondokuz Mayis University, between April 2011 and October 2021 were retrospectively analyzed. Age, gender, and diagnosis information were recorded for each case. Patients were grouped into general anesthesia, sedation, no sedation groups. The evaluation of magnetic resonance images was performed by a specialized in neuroradiology. The radiologist classified the image quality as good, moderate, or poor based on artifacts resulting from unwanted motion. Results: A total of 127 patients, out of 190 patients, were included in the study. There were no significant differences in image quality based on anesthesia/sedation method and airway management (p>0.05). No significant differences were observed in the number of repeated sequences when compared based on anesthesia/sedation method and airway management (p>0.05). Conclusion: General anesthesia, sedation, or no sedation during preoperative magnetic resonance imaging in patients with movement disorders did not result in significant differences in image quality and the number of sequences requiring repetition.
dc.description.sponsorshipTıbbi Kayıtlar Derneği
dc.identifier.doi10.37990/medr.1330987
dc.identifier.endpage21
dc.identifier.issn2687-4555
dc.identifier.issueSupplement (1)
dc.identifier.startpage16
dc.identifier.urihttps://hdl.handle.net/20.500.14034/2638
dc.identifier.urihttps://doi.org/10.37990/medr.1330987
dc.identifier.volume5
dc.language.isoen
dc.publisherTıbbi Kayıtlar Derneği
dc.relation.ispartofMedical Records
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_DergiPark_20250319
dc.subjectDeep brain stimulation
dc.subjectMagnetic resonance imaging
dc.subjectMovement Disorders
dc.subjectParkinson’s disease
dc.subjectAnesthesia
dc.subjectSedation
dc.titleAssociation between Anesthesia Management and Preoperative Magnetic Resonance Image Quality in Patients Scheduled for Deep Brain Stimulation Surgery