Efficacy of balanced torsional phacoemulsification tip for cataract surgery
dc.contributor.author | Sabur, Huri | |
dc.contributor.author | Eroğlu, Sayime Aydın | |
dc.contributor.author | Azarsız, Salih Sertaç | |
dc.date.accessioned | 2023-03-22T19:47:26Z | |
dc.date.available | 2023-03-22T19:47:26Z | |
dc.date.issued | 2022 | |
dc.department | Belirlenecek | en_US |
dc.description.abstract | Purpose: To compare the efficacy of the Intrepid((R)) Balanced torsional phacoemulsification tip to that of the 30 degrees Ozil((R)) and 45 degrees Kelman((R)) tips using Centurion Vision System. Methods: This study included 150 eyes that underwent torsional phacoemulsification surgery using 30 degrees Ozil((R)) tip (Group 1, 48 eyes), Intrepid((R)) Balanced tip (Group 2, 52 eyes), or 45 degrees Kelman((R)) tip (Group 3, 50 eyes). Ultrasound time (UST), cumulative dissipated energy (CDE), average phaco power, average torsional amplitude, balanced salt solution volume, aspiration and operation time, and preoperative, postoperative corrected distance visual acuity, central corneal thickness were recorded. Results: The mean UST, CDE, average phaco power, average torsional amplitude were 49.9 +/- 15.7 s, 10.8 +/- 4.5%-s, 23.9 +/- 4.6%, and 51.4 +/- 5.7% in the Ozil((R)) group and 47.5 +/- 10.6 s, 5.3 +/- 2.2%-s, 12.5 +/- 5.3%, and 28.9 +/- 7.2% in the Intrepid((R)) Balanced group, and 48.1 +/- 12.7 s, 6.9 +/- 3.3%-s, 18.9 +/- 5.9%, and 39.2 +/- 7.9% in the Kelman((R)) group, respectively. The CDE, average phaco power, and average torsional amplitude of the Intrepid((R)) Balanced group were significantly lower than other groups (P < 0.05). There was no statistically significant difference between the three groups in terms of UST and operation time (P > 0.05). Conclusion: Intrepid((R)) Balanced tip, by means of its distinctive double bent design and balanced energy distribution, offers more effective phacoemulsification compared to conventional 30 degrees Ozil((R)) and 45 degrees Kelman((R)) tips. | en_US |
dc.identifier.doi | 10.4103/joco.joco_105_21 | |
dc.identifier.endpage | 79 | en_US |
dc.identifier.issn | 2452-2325 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 35620374 | en_US |
dc.identifier.scopus | 2-s2.0-85128976558 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 74 | en_US |
dc.identifier.uri | https://doi.org/10.4103/joco.joco_105_21 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14034/702 | |
dc.identifier.volume | 34 | en_US |
dc.identifier.wos | WOS:000919323600001 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wolters Kluwer Medknow Publications | en_US |
dc.relation.journal | Journal Of Current Ophthalmology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Intrepid balanced phaco tip | en_US |
dc.subject | Kelman phaco tip | en_US |
dc.subject | Ozil phaco tip | en_US |
dc.subject | Phaco tip | en_US |
dc.subject | Torsional phacoemulsification | en_US |
dc.subject | Outcomes | en_US |
dc.subject | Energy | en_US |
dc.title | Efficacy of balanced torsional phacoemulsification tip for cataract surgery | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Efficacy of Balanced Torsional Phacoemulsification Tip for.pdf
- Boyut:
- 1.1 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin / Full text