Efficacy of balanced torsional phacoemulsification tip for cataract surgery

dc.contributor.authorSabur, Huri
dc.contributor.authorEroğlu, Sayime Aydın
dc.contributor.authorAzarsız, Salih Sertaç
dc.date.accessioned2023-03-22T19:47:26Z
dc.date.available2023-03-22T19:47:26Z
dc.date.issued2022
dc.departmentBelirleneceken_US
dc.description.abstractPurpose: To compare the efficacy of the Intrepid((R)) Balanced torsional phacoemulsification tip to that of the 30 degrees Ozil((R)) and 45 degrees Kelman((R)) tips using Centurion Vision System. Methods: This study included 150 eyes that underwent torsional phacoemulsification surgery using 30 degrees Ozil((R)) tip (Group 1, 48 eyes), Intrepid((R)) Balanced tip (Group 2, 52 eyes), or 45 degrees Kelman((R)) tip (Group 3, 50 eyes). Ultrasound time (UST), cumulative dissipated energy (CDE), average phaco power, average torsional amplitude, balanced salt solution volume, aspiration and operation time, and preoperative, postoperative corrected distance visual acuity, central corneal thickness were recorded. Results: The mean UST, CDE, average phaco power, average torsional amplitude were 49.9 +/- 15.7 s, 10.8 +/- 4.5%-s, 23.9 +/- 4.6%, and 51.4 +/- 5.7% in the Ozil((R)) group and 47.5 +/- 10.6 s, 5.3 +/- 2.2%-s, 12.5 +/- 5.3%, and 28.9 +/- 7.2% in the Intrepid((R)) Balanced group, and 48.1 +/- 12.7 s, 6.9 +/- 3.3%-s, 18.9 +/- 5.9%, and 39.2 +/- 7.9% in the Kelman((R)) group, respectively. The CDE, average phaco power, and average torsional amplitude of the Intrepid((R)) Balanced group were significantly lower than other groups (P < 0.05). There was no statistically significant difference between the three groups in terms of UST and operation time (P > 0.05). Conclusion: Intrepid((R)) Balanced tip, by means of its distinctive double bent design and balanced energy distribution, offers more effective phacoemulsification compared to conventional 30 degrees Ozil((R)) and 45 degrees Kelman((R)) tips.en_US
dc.identifier.doi10.4103/joco.joco_105_21
dc.identifier.endpage79en_US
dc.identifier.issn2452-2325
dc.identifier.issue1en_US
dc.identifier.pmid35620374en_US
dc.identifier.scopus2-s2.0-85128976558en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage74en_US
dc.identifier.urihttps://doi.org/10.4103/joco.joco_105_21
dc.identifier.urihttps://hdl.handle.net/20.500.14034/702
dc.identifier.volume34en_US
dc.identifier.wosWOS:000919323600001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.journalJournal Of Current Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIntrepid balanced phaco tipen_US
dc.subjectKelman phaco tipen_US
dc.subjectOzil phaco tipen_US
dc.subjectPhaco tipen_US
dc.subjectTorsional phacoemulsificationen_US
dc.subjectOutcomesen_US
dc.subjectEnergyen_US
dc.titleEfficacy of balanced torsional phacoemulsification tip for cataract surgeryen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Efficacy of Balanced Torsional Phacoemulsification Tip for.pdf
Boyut:
1.1 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin / Full text