Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Zoghi, Mehdi" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Evaluation of alveolar-capillary membrane functions by thoracic ultrasonography in heart failure
    (2024) Gurses, Ecem; Zoghi, Mehdi
    Objectives: This study aimed to research the effect of the increased B-line count (interstitial fluid accumulation) in patients with congestive heart failure on the diffusion capacity of the alveolar-capillary membrane. Patients and methods: This prospective study was conducted with 77 inpatients diagnosed with pulmonary edema and decompensated heart failure between January 2018 and December 2018. The B-line counts of the patients were calculated through echocardiography and thoracic ultrasonography within the first 24 h of their admission, and the patients were categorized into two groups based on their B-line counts being <15 (n=26; 18 males, 8 females; mean age: 48.6±3.3 years; range, 21 to 72 years) or >15 (n=51; 36 males, 15 females; mean age: 53.7±2.0 years; range, 20 to 79 years). After sufficient diuretic treatment, the patients who were able to tolerate and pass the tests were then subjected to a respiratory function test, diffusion test [DLCO (diffusing capacity of the lungs for carbon monoxide)], and six-minute walk test (6MWT). Results: The following results in study were found in the echocardiography of the patients with a B-line number >15: lower right ventricular ejection fraction (p=0.003), lower right ventricular systolic motion (p=0.014), higher systolic pulmonary artery pressure (p<0.0001), higher tricuspid regurgitant velocity (p=0.001), more dilated vena cava inferior radius (p<0.0001), higher left atrium volume (p=0.007), higher early diastolic transmitral flow velocity/early diastolic mitral anullar velocity (E/e´) >15 (p<0.0001), and higher pleural effusion (p=0.014). The following results were found in the respiratory function test, DLCO test, and 6MWT of the patients with a B-line number >15: lower forced vital capacity (p<0.0001), lower forced expiratory volume in 1 sec (p=0.002), lower corrected DLCO (p<0.0001), lower 6MWT (p<0.0001). Conclusion: B-line counts >15 may be a predictor of a decrease in diffusion capacity, restrictive pattern in respiratory function, decrease in right ventricular function, and increase in pulmonary vascular resistance.

| İzmir Bakırçay Üniversitesi | Kütüphane | Açık Bilim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Gazi Mustafa Kemal Mahallesi, Kaynaklar Caddesi Seyrek,Menemen, İzmir, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim