Yazar "Colak, Ayfer" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Evaluation of D-dimer levels measured by different analytical methods in COVID-19 patients(Lippincott Williams & Wilkins, 2022) Arslan, Fatma Demet; Basok, Banu Isbilen; Terzioglu, Mustafa; Altan, Tuba Kansu; Karaca, Yeser; Senger, Suheyla Serin; Colak, AyferClinicians experience some challenges due to the lack of standardization of test, although D-dimer is a prognostic marker for COVID-19. We compared the clinical and analytical performances of D-dimer results obtained from different devices, kits and methods in patients with a diagnosis of COVID-19. Thirty-nine patients with a diagnosis of COVID-19 and 24 healthy individuals were included in the study. D-dimer levels were measured with Innovance D-DIMER kit (immunoturbidimetric method) on Sysmex CS-2500 and BCS XP and VIDAS D-Dimer Exclusion II kit (enzyme-linked fluorescence method) on mini VIDAS. The studies of precision, method comparison and clinic performance were performed. The variation coefficients in all systems were within the acceptable imprecision (7.8%). Bias%(12.5%) between BCS XP and Sysmex CS-2500 was lower than the acceptable Bias%(15.5%). Bias% values (19.2% and 33.3%, respectively) between Mini VIDAS with BCS XP and Sysmex CS-2500 were higher than the acceptable Bias%. The correlation coefficients among all systems were 0.89-0.98. For 500 ng/ml FEU, there was almost perfect agreement between BCS XP and Sysmex CS-2500, a moderate agreement between Mini VIDAS and BCS XP and Sysmex CS-2500. The cut-off values for distinguishing between individuals with and withoutCOVID-19 were Mini VIDAS, Sysmex CS-2500 and BCS XP 529, 380 and 390 ng/ml FEU, respectively. The immunoturbidimetric method can be used as an alternative to the enzyme-linked fluorescent method because of satisfactory agreement at the different thresholds proposed for venous thromboembolism. However, it is recommended to follow up COVID-19 with the D-dimer results obtained by the same assay system.Öğe Stability of potassium, calcium and phosphorus electrolytes in three different tubes in patients with essential thrombocytosis(Taylor & Francis Ltd, 2023) Aksit, Murat; Zeytinli Aksit, Merve; Colak, Ayfer; Isbilen Basok, Banu; Ceylan, CengizProper blood collection and timely analysis are vital steps for reliable results. This study aims to compare potassium(K), calcium(Ca), and phosphorus(P) concentrations in serum separator tube (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with a barrier (Barricor)tubes in essential thrombocytosis(ET) patients. Additionally, we assessed short-term stability of these analytes at room temperature. K, Ca and P concentrations of blood taken from 40 ET patients into SST, LiH and Barricor tubes were measured at 0, 2, 4 and 8 h. We calculated the percentage difference and defined the maximum permissible difference (MPD) using the Biological Variation Database. Intertube comparisons were conducted using Passing-Bablok regression and Bland-Altman analysis. Comparing SST to LiH, the percentage difference values for all tests exceeded the MPD. When comparing Barricor to LiH, K and Ca tests were above MPD, except for P. At the 8th hour, LiH showed clinically significant changes in all three electrolytes. Barricor exhibited stability for K, Ca, and P for up to 8 h, with only Ca levels borderline higher than the MPD. Our study reveals clinically significant alterations in K, Ca, and P concentrations in SST compared to LiH tubes, and in K and Ca concentrations in Barricor compared to LiH tubes. While K, Ca and P concentrations were stable for up to 4 h at room temperature in all tube types tested, significant changes were observed in all electrolytes at 8 h in the LiH tube.Öğe Usefulness of laboratory parameters and chest CT in the early diagnosis of COVID-19(Inst Medicina Tropical Sao Paulo, 2022) Colak, Ayfer; Oncel, Dilek; Altin, Zeynep; Turken, Melda; Arslan, Fatma Demet; Iyilikci, Veli; Yilmaz, NiselIn the present study, the importance of laboratory parameters and CT findings in the early diagnosis of COVID-19 was investigated. To this end, 245 patients admitted between April 1st, and May 30th, 2020 with suspected COVID-19 were enrolled. The patients were divided into three groups according to chest CT findings and RT-PCR results. The non-COVID-19 group consisted of 71 patients with negative RT-PCR results and no chest CT findings. Ninety-five patients with positive RT-PCR results and negative chest CT findings were included in the COVID-19 group; 79 patients with positive RT-PCR results and chest CT findings consistent with COVID-19 manifestations were included in COVID-19 pneumonia group. Chest CT findings were positive in 45% of all COVID-19 patients. Patients with positive chest CT findings had mild (n=30), moderate (n=21) andor severe (n=28) lung involvement. In the COVID-19 group, CRP levels and the percentage of monocytes increased significantly. As disease progressed from mild to severe, CRP, LDH and ferritin levels gradually increased. In the ROC analysis, the area under the curve corresponding to the percentage value of monocytes (AUC=0.887) had a very good accuracy in predicting COVID-19 cases. The multinomial logistic regression analysis showed that CRP, LYM and % MONO were independent factors for COVID-19. Furthermore, the chest CT evaluation is a relevant tool in patients with clinical suspicion of COVID-19 pneumonia and negative RT-PCR results. In addition to decreased lymphocyte count, the increased percentage of monocytes may also guide the diagnosis.